Search results for "specular microscopy"

showing 8 items of 8 documents

Quantitative anatomical differences in central corneal thickness values determined with scanning-slit corneal topography and noncontact specular micr…

2005

PURPOSE This study was designed to analyze the differences in central corneal thickness values determined with noncontact specular microscopy and scanning-slit corneal topography. The measurements were performed on the same eye. METHODS We analyzed the central corneal thickness values of 93 patients (n = 93) by means of noncontact specular microscopy (Topcon SP-2000P noncontact specular microscope, Topcon Corp., Tokyo, Japan) and scanning-slit corneal topography (Orbscan Topography System II, Orbscan Inc., Salt Lake City, UT). One experienced physician performed 3 consecutive central corneal thickness measurements with both devices. RESULTS The central corneal thickness values obtained by m…

Adultmedicine.medical_specialtyMicroscopyMaterials sciencegenetic structuresmedicine.diagnostic_testbusiness.industryCorneal TopographyReproducibility of ResultsCorneal topographySliteye diseasesSalt lakeCorneaOphthalmologyOpticsReference ValuesOphthalmologySPECULAR MICROSCOPYmedicineHumanssense organsProspective StudiesbusinessCornea
researchProduct

Granulometric moments and corneal endothelium status

2001

Abstract Specular microscopy is a common practice in Ophthalmology. The corneal endothelium status is usually evaluated by means of the density, the hexagonality, the mean, the standard deviation and the coefficient of variation of cell areas. We propose to replace the cell area moments by the corresponding moments of a different probability distribution, the granulometric size distribution associated to a disc. All cells touching the frame are ignored by the area moments but used by the granulometric moments. Twenty images have been analyzed. When the size of the focused region is reduced, the area moments show a greater variation than the corresponding granulometric moments.

Corneal endotheliumArtificial IntelligenceCoefficient of variationSignal ProcessingMathematical analysisSPECULAR MICROSCOPYStatisticsProbability distributionComputer Vision and Pattern RecognitionSoftwareStandard deviationShape analysis (digital geometry)MathematicsPattern Recognition
researchProduct

Granulometric analysis of corneal endothelium specular images by using a germ–grain model

2007

Specular microscopy is widely used to study the human corneal endothelium status in vivo. In this paper, the corneal endothelium is represented as a binary image composed of the cell inscribed circles. The granulometric distribution function of the complement of this image is used as a functional descriptor, which provides information about the shape, size and spatial arrangement of cells. Experimental evaluation using bootstrap techniques shows its ability to discriminate between controls and pathological cases. It represents a reliable and graphical alternative to the classical indices (cell density, hexagonality and coefficient of variation of cell areas), which behave poorly when detect…

Corneal endotheliumMaterials sciencegenetic structuresCell CountHealth InformaticsCell densityImage Processing Computer-AssistedHumansComputer SimulationComputer visionGermSpecular reflectionCell SizeMicroscopyFourier Analysisbusiness.industryBinary imageEndothelium CornealNumerical Analysis Computer-AssistedComputer Science ApplicationsOphthalmoscopySPECULAR MICROSCOPYArtificial intelligenceBiological systembusinessSoftwareShape analysis (digital geometry)Computers in Biology and Medicine
researchProduct

Classifying human endothelial cells based on individual granulometric size distributions

2002

Abstract This paper presents an application to a medical problem of methods of shape analysis based on mathematical morphology. The medical problem consists on the detection of abnormalities in the corneal endothelium, a tissue composed by quasi-planar cells of ideally regular hexagonal shape. Images of this tissue are taken by a specular microscope and used to evaluate the corneal endothelium status. Up to now, cell density, hexagonality and an analysis of cell areas are the usual descriptors of a corneal endothelium. These parameters are not sensitive enough to detect subtle lesions. What this paper proposes is an analysis based on granulometries, which are size-shape descriptors widely u…

Corneal endotheliumgenetic structuresComputer scienceHexagonal crystal systemSignal ProcessingCell densitySPECULAR MICROSCOPYCell analysisComputer Vision and Pattern RecognitionMathematical morphologyBiological systemShape analysis (digital geometry)Image and Vision Computing
researchProduct

Set Descriptors for Visual Evaluation of Human Corneal Endothelia

2001

Images of corneal endothelium obtained from specular microscopy are of great importance in the evaluation of the corneal endothelium status. Several commercial tools provide some numerical descriptors to characterize these images in terms of cell density, hexagonality, and some descriptive statistics of the cell areas. However, it is a too simple analysis that only detects severe abnormal endothelia with many irregular and large cells. Detection of subtle abnormalities needs a more refined analysis. This paper proposes a shape-size descriptor based on some modified versions of the geometric covariogram. This descriptor is presented as a valid alternative to the classical analysis that provi…

Corneal endotheliumgenetic structuresbusiness.industryComputer scienceSet (abstract data type)Signal ProcessingNumerical descriptorsCell densitySPECULAR MICROSCOPYcardiovascular systemComputer visionComputer Vision and Pattern RecognitionArtificial intelligencebusinessSoftwareComputer Vision and Image Understanding
researchProduct

Crystalline subtype of pre-descemetic corneal dystrophy.

2014

Purpose: To report corneal findings in a familial case of the crystalline subtype of pre- Descemetic corneal dystrophy. Case Report: A 19-year-old girl and her 44-year-old mother were found to have asymptomatic, bilateral, punctiform and multi-colored crystalline opacities across the whole posterior layer of the corneas. Endothelial specular microscopy revealed the presence of white round flecks located at different levels anterior to the endothelium. No systemic abnormalities or medications could be related to account for these findings. Conclusion: To the best of our knowledge, this is the third familial report of this rare corneal disorder. Differential diagnosis may include Schnyder cor…

Crystalline Subtype Pre-Descemetic Corneal Dystrophylcsh:Ophthalmologygenetic structureslcsh:RE1-994Crystalline Corneal Deposition Specular MicroscopyCase ReportCrystalline Subtype Pre-Descemetic Corneal Dystrophy; Crystalline Corneal Deposition Specular Microscopysense organseye diseases
researchProduct

Inter-observer variability of central corneal thickness measurements using non-contact specular microscopy after laser in situ keratomileusis.

2003

BACKGROUND The aim of this study was to investigate the inter-observer variability of central corneal thickness measurements carried out with a non-contact specular microscope in patients who had undergone myopic laser in situ keratomileusis. METHODS Twenty-six eyes of 26 subjects who had undergone myopic laser in situ keratomileusis were studied with the Topcon SP-2000P non-contact specular microscope (Topcon Corp, Tokyo, Japan). The mean of three consecutive measurements of the central corneal thickness was recorded by two investigators prior to and one month after myopic laser in situ keratomileusis. Results obtained by each of the two physicians were compared. RESULTS Prior to surgery t…

In situAdultMalemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituKeratomileusislaw.inventionCornealawOphthalmologymedicineMyopiaHumansBody Weights and MeasuresPostoperative PeriodObserver VariationMicroscopyExcimer laserbusiness.industryLASIKLasereye diseasesConfidence intervalOphthalmologySPECULAR MICROSCOPYOptometryFemalesense organsbusinessObserver variationOptometryClinicalexperimental optometry
researchProduct

Endothelial cells loss to the hyperopic pacients during phacoemulsification

2018

Introduction The phacoemulsification cataract surgery is the most frequently performed surgery and it generally improves vision in over 90% of the patients. Hyperopic patients are a challenge during phacoemulsification especially because of their short eyeball and shallow anterior chamber. A shallow anterior chamber is associated with overall reduction of the safe zone, which may lead to difficulty in creating the corneal incisions, harder capsulorhexis performing, or endothelial complications. Purpose The aim of the study was to present the endothelial cells loss after the phacoemulsification procedure in the hyperopic patients. Material and methods A number of 1775 patients operated in th…

hyperopiaspecular microscopyCorneal endotheliummedicine.medical_specialtygenetic structuresEndotheliummedicine.medical_treatmentHypermetropiaEmmetropiaCataractLens Implantation IntraocularCorneaOphthalmologymedicineHumansCapsulorhexisPhacoemulsificationbusiness.industryEndothelium Cornealshallow anterior chamberEndothelial CellsGeneral MedicinePhacoemulsificationCataract surgeryeye diseasesmedicine.anatomical_structureGeneral ArticlesbusinessRomanian Journal of Ophthalmology
researchProduct